Explosion Proof Static Eliminator BarXP-2 Static Bar

The XP-2 is UL listed for Class I, Divisions 1 and 2, Group D Hazardous Locations and FM approved when used with a Simco XP167 or XP267 Power Supplies, which can be mounted within the hazardous area. The XP-2 is also approved for use with the N167 or N267 Power Supplies, which must be mounted outside the hazardous area, in electrostatic finishing processes involving spray painting, dipping, coating, and liquid printing processes.

The XP-2 has 1/2" NPT male threads at the cable end of the bar for connection to rigid or flexible metal conduit . All conduit runs are then sealed at the power supply enclosure. See the XP167 Power Supply dimensional drawing in the Power Supply section for conduit length allowances.

We recommend that you call C.C. Steven at 805-658-0207 if you are not already familiar with installing and operating this equipment.

UL Listed for Class I, Division 1 and 2, Group D hazardous locations and FM approved.
FAQ     Static Bar Comparison Chart     Dimensional Drawing(86kB)     Return to Static Bars

Specification:

Shockless or Hot

Shockless

Ionization Output

Standard

Maximum speed of target material

1000 ft/min

How far from charged material can bar be mounted?

1 inch

Approved for hazardous locations

Yes

Intended for heavy, normal or light industrial applications

Any

Maximum overall length

142 1/2 inches


Design Your XP-2 Static Bar

It's easy to configure and order a Simco XP-2 static bar to fit your requirements. They are available in 3/4” increments starting with overall lengths from  4.5” with a single ionizing emitter pin up to 142.5” with 138” of ionizing emitter pins. All XP-2 static bars are shipped with  high voltage cable and one EY X-proof fitting and compound.  Standard high voltage cable length is 10-ft.  Longer lengths can be made if required.

Simply select the overall length of the static bar you need and determine if additional cable length is required to reach the power supply mounting location.   Then E-mail us or call C.C. Steven at 805-658-0207 and we’ll have one built for you!

You must order a power supply to power the static bar if you do not already have one. We recommend the following models for the XP-2 Static Bar.

Power Supply

Part Number

XP167 - 120V, 60 Hz, 7 kV, 3mA max, 4 output, use inside hazardous area

IPS0600

XP267 - 230V, 60 Hz, 7 kV, 3mA max, 4 output, use inside hazardous area

IPS0601

XPM167 - 120V, 60 Hz, 7 kV, 3mA max, 4 output, use outside hazardous area

IPXPM01

XPM267 - 230V, 60 Hz, 7 kV, 3mA max, 4 output, use outside hazardous area

IPXPM02