mailers

Static Control Nozzles for Industrial, Medical, Printing and Converting Industries

C.C.Steven & Associates, 1363 Donlon Street Ventura, CA 93003   since 1978  

ph:  805-658-0207          fax: 805-658-2789           static@ccsteven.com

[CCSteven.com] [Static Control] [Ionizing Nozzles] [HSHeader]

HS Nozzles Mounted on an Air Header Bar

HS Nozzles Mounted on an Air Header Bar
Here's a way to make nozzle installation a snap.

Have us mount your HS Nozzles on an air header bar. This makes it easy for you to install and hookup your nozzles. You get our high quality, high performing HS Nozzles, plus an aluminum air header. Simply mount the air header, make one compressed air connection to the header, attach the high voltage cable to the power supply, and you're ready to go!

Ask about our NEW Modular Dust Catcher for source capturing the particulate you are using the HS Nozzles to blow off!
HS Nozzles are UL, CSA, and FM approved.
FAQ    Applications     Dimensional Drawing(81kB)     Return to Nozzles

Line Voltage Requirements

115 V, 50/60 Hz    230 V, 50/60 Hz

Size (Individual Nozzle)

2 9/16" H x 13/16" W x 2 1/2" L

Maximum Air Pressure (clean, dry air)

100 psi maximum

Air Flow (at 30 psi)

4.4 SCFM

Air Supply Connection

1/8" NPT on nozzle   3/8" NPT on header

Working Distance from substrate

3" to 10"

Operating Temperature Limit

150° F (66° C)

Static Charge Discharge Time

0.6 seconds at 6" at 30 psi (5000 V to 500 V)

Design Your HS Nozzles Mounted on an Air Header Bar

It's easy to order HS nozzles mounted on air header bars. First, select the number of nozzles you want on the header.
Next,  decide the distance between each nozzle (nozzle tip to nozzle tip) on the header in increments of 1”. Minimum spacing is 3”.
Finally, decide if you want stopcocks (on/off valves to control airflow on the individual nozzles).

The standard header supplied will be have end dimension 2” longer than position of last nozzle measured from the nozzle tip. An air valve is included in the pricing and supplied at one end of the header. Headers with more than 12 nozzles are supplied with valves at each end.

Questions? Ready to order? E-mail us or call C.C. Steven at 805-658-0207.

You must order a power supply to power the nozzles if you do not already have one. We recommend
the following models for the HS Nozzles Mounted on an Air Header Bar.

Power Supply

Part Number

F167 - 120V, 50/60 Hz, 7 kV, 3mA max, 2 output

IPF0300

F167S - 120V, 50/60 Hz, 7 kV, 3mA max, lighted power switch

IPF03S0

F267 - 230V, 50/60 Hz, 7 kV, 3mA max, 2 output

IPF0301

F267S - 230V, 50/60 Hz, 7 kV, 3mA max, lighted power switch

IPF03S1

N167 - 120V, 60Hz, 7 kV, 3mA max, 4 output

IPN0519

N267 - 230V, 60Hz, 7 kV, 3mA max, 4 output

IPN0515

N257 - 230V, 50Hz, 7 kV, 3mA max, 4 output

IPN0516

Visit our other sites to further enhance your manufacturing operations.  Click on a button below: